:: Volume 7, Issue 2 ( Spring 2020) ::
Environ. Health Eng. Manag. 2020, 7(2): 79-88 Back to browse issues page
Application of heterogeneous catalytic ozonation process for treatment of high toxic effluent from a pesticide manufacturing plant
Mina Ghahrchi , Edris Bazrafshan , Behruz Adamiyat Badan , Yousef Dadban Shahamat * , Fariba Gohari
Corresponding author:Environmental Health Research Center, Department of Environmental Health Engineering, Faculty of Health, Golestan University of Medical Sciences, Golestan, Iran , Dr.udadban@goums.ac.ir
Abstract:   (5365 Views)
Background: The discharge of untreated wastewater containing toxic and resistant compounds into the environment is a serious threat for ecosystems. Therefore, this study was conducted to evaluate the treatment of poison production factory wastewater using heterogeneous catalytic ozonation process
(COP).
Methods: Magnetic carbon nanocomposite was used as a catalyst at concentrations of 1, 2, and 4 g/L. Its effect on improving the treatment process was evaluated at reaction time of 30, 60, 90, and 120 minutes. At the end of each experiment, parameters including total organic carbon (TOC), chemical oxygen demand (COD), biological oxygen demand (BOD5), pH, electrical conductivity (EC), and turbidity were measured.
Results: It was revealed that in single ozonation process (SOP), the maximum removal efficiencies of TOC, COD, and BOD5 were achieved at reaction time of 120 minutes as 56%, 40%, and 11.7%, respectively. By adding the catalyst to the wastewater, the treatment process was improved, so that the
maximum removal efficiencies of COD (91%), TOC (73%), and BOD5 (74%) were obtained at catalyst concentration of 4 g/L. Under this condition, BOD5/COD ratio increased from 0.22 to 0.64. Also, the results of analysis of ozone consumption per each mg of reduced COD showed that its amount sharply decreased from 2.1 mgO3/mg COD removal in the SOP, to 0.34 mgO3/mg COD removal in the COP. The results of kinetic reaction analysis also revealed that the rate constant increased from 0.007 to 0.02 min-1.
Conclusion: According to the results, it can be concluded that the COP at a catalyst concentration of 4 g/L, by decomposing resistant compounds and increasing the biodegradability, can be used as a suitable pre-treatment method for biological processes.
Keywords: Wastewater, Treatment, Nanocomposite, Catalytic ozonation, Kinetics
eprint link: http://eprints.kmu.ac.ir/id/eprint/32722
Full-Text [PDF 1782 kb]   (2524 Downloads)    
Type of Study: Original Article | Subject: General
Received: 2020/06/14 | Revised: 2020/08/19 | Accepted: 2020/06/14 | Published: 2020/06/14

Ethics code: ir.goums.rec.1396.14



XML     Print



Rights and permissions
AWT IMAGE This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 7, Issue 2 ( Spring 2020) Back to browse issues page