[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Open Access
AWT IMAGE
..
MeSH Browser

AWT IMAGE

..
Scopus quartile
..
Google Scholar

Citation Indices from GS

AllSince 2019
Citations27952419
h-index2422
i10-index9680

..
ORCID
..
:: Volume 10, Issue 4 (Autumn 2023) ::
Environ. Health Eng. Manag. 2023, 10(4): 451-458 Back to browse issues page
Investigating the performance of urban air quality monitoring station in measuring PM2.5 and PM10: A case study in Tehran, Iran
Zahra Aboosaedi , Kazem Naddafi , Ramin Nabizadeh Nodehi , Mohammad Sadegh Hassanvand , Sasan Faridi , Rasoul Aliannejad
Corresponding author: Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran , knadafi@tums.ac.ir
Abstract:   (621 Views)
Background: In recent years, new findings on the relationship between human health and air pollutants have emerged, underscoring the necessity for appropriate site selection of air monitoring stations.
Methods: This analytical-cross-sectional study aimed to compare the concentration levels of PM10 and PM2.5, as measured by weight method, with data collected from an air quality monitoring station (AQMS) in Tehran. Initially, data were collected from the Tarbiat Modares AQMS. The accuracy of this data was then evaluated using a high-volume sampler and Grimm dust monitor situated approximately 200 meters away from the Tarbiat Modares station. The study period was between June 2017 and October 2017, and the frequency of sampling was every six days according to the instructions.
Results: The results revealed that the average concentration levels of PM10, as measured during the sampling period by the high-volume sampler, the Grimm device, and the air quality measurement station, were 143.54 ± 33.84, 70.95 ± 7.06, and 110.06 ± 27.08 μg.m-3, respectively. The highest daily concentration of PM10 was recorded by the high-volume sampler device at 197.12 μg.m-3.
Conclusion: This study found a weak correlation between the aerosol concentration data obtained from the monitoring station and those obtained from the Grimm device and the high-volume sampler. Therefore, it is crucial to ensure the quality control and assurance of data collected from monitoring stations for accurate decision-making and planning.
Keywords: Air pollution, Particulate matter, Validation study, Dust, Cross-sectional studies
Full-Text [PDF 927 kb]   (490 Downloads)    
Type of Study: Original Article | Subject: General
Received: 2023/10/31 | Accepted: 2023/10/18 | Published: 2023/12/26
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA

Ethics code: IR.TUMS.SPH.REC.1396.2171



XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Aboosaedi Z, Naddafi K, Nabizadeh Nodehi R, Hassanvand M S, Faridi S, Aliannejad R. Investigating the performance of urban air quality monitoring station in measuring PM2.5 and PM10: A case study in Tehran, Iran. Environ. Health Eng. Manag. 2023; 10 (4) :451-458
URL: http://ehemj.com/article-1-1218-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 10, Issue 4 (Autumn 2023) Back to browse issues page
Environmental Health Engineering And Management Journal Environmental Health Engineering And Management Journal
Persian site map - English site map - Created in 0.1 seconds with 46 queries by YEKTAWEB 4645