[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Open Access
AWT IMAGE
..
MeSH Browser

AWT IMAGE

..
Scopus quartile
..
Google Scholar

Citation Indices from GS

AllSince 2019
Citations27762400
h-index2422
i10-index9679

..
ORCID
..
:: Volume 5, Issue 3 (Summer, 2018) ::
Environ. Health Eng. Manag. 2018, 5(3): 129-136 Back to browse issues page
Investigation of the relationship between depth of overhang and amount of daylight indicators in office buildings of Kerman city
Ali Yazhari Kermani , Farshad Nasrollahi , Mohammadjavad Mahdavinejad
Corresponding Author: Department of Architecture, School of Architecture and Urbanism, Art University of Isfahan, Isfahan, Iran , f.nasrollahi@aui.ac.ir
Abstract:   (5505 Views)
Background: The use of daylight in offices has become an effective strategy to improve the quality of indoor space and energy efficiency. There is enough potential to have daylight autonomy in Kerman as a city with more than 300 sunny days a year. Therefore, this study aimed to investigate the relationship
between facades configuration and the amount of daylight in office buildings of Kerman.
Methods: This study was carried out based on the simulation in DesignBuilder software (DBS). In this study, 36 typical rooms, with the same physical characteristics (4 m×6 m×4 m), with window-to-wall ratio (WWR) between 10- 90% with four overhang depths (0, 0.5, 1 and 1.5 m) were modeled.
Results: Based on daylight utilization, the results indicate that an optimal WWR for a room with 1 m overhang depth ranged from 50% to 70%. Also, the room with 0.5 m overhang depth and without overhang, had suitable daylight while WWR was at least 50%, but the room with 1.5 m depth would not
encounter glare problem even when WWR was 90%.
Conclusion: The results confirm that overhang depth and WWR have significant effect on daylight parameters such as daylight factor (DF), work plane illuminance (WPI), and WPI ratio. Hence, these insights can be useful for designers to design buildings with lower energy use and higher daylight
quality, when enough light is provided in office rooms.
Keywords: Sunlight, Office, Kerman, Uniformity, Design software
eprint link: http://eprints.kmu.ac.ir/id/eprint/29069
Full-Text [PDF 487 kb]   (2587 Downloads)    
Type of Study: Original Article | Subject: Special
Received: 2018/10/17 | Accepted: 2018/10/17 | Published: 2018/10/17
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA



XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Yazhari Kermani A, Nasrollahi F, Mahdavinejad M. Investigation of the relationship between depth of overhang and amount of daylight indicators in office buildings of Kerman city. Environ. Health Eng. Manag. 2018; 5 (3) :129-136
URL: http://ehemj.com/article-1-372-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 5, Issue 3 (Summer, 2018) Back to browse issues page
Environmental Health Engineering And Management Journal Environmental Health Engineering And Management Journal
Persian site map - English site map - Created in 0.05 seconds with 47 queries by YEKTAWEB 4645